Rainwater filter for bigger roof areas. The Twin Filter can be installed in a pilot shaft or in frost-protected regions directly on the wall. Normally standard concrete shafts are used (Ø 1000 mm). The filter can be delivered to the site pre-installed in the shaft.
Two step cleaning system, therefore high level of filtering efficiency, independent of flow rate. Due to the steep inclination of the filter cartridge the dirt is continuously cleaned away into the sewer. The cleaned water is collected in a tank and directed into the storage.
Connection capacity for roof areas up to 700 m². Because of a Bypass-Installation a bigger area can be connected.
Max. Flow Rate Sieve insert 3,0/sec = 10,8 m³ cleaned water per hour.
Rainwater inlet: 2 x DN 100/ DN 150
Tank inlet: 2 x DN 100/DN 150
Outlet into sewer: 2 x DN 100/ DN 150
The filter has to be cleaned depending on the contamination 1 - 2 times during the year.
1. As water arrives the level builds up and is equally distributed across the two cascades.
2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.
3. Pre filtered water then flows over the secondary filter sieve (mesh size 0,65 mm). Due to the special mesh structure of the sieve, any dirt washes directly into the sewer.
4. The cleaned water is being absorbed in the middle tank and directed through one or the two connections into the storage.
5. Dirt goes to the sewer through the shaft.
Rainwater inlet: 2 x DN 100/ DN 150
Tank inlet: 2 x DN 100/ DN 150
Outlet into sewer: 2 x DN 100/ DN 150
Height difference between inlet and
a. outlet into the storage: 350 mm
b. outlet into the sewer: 510 mm
Housing and cascade material: Polyethylen
Filter cartridge: Stainless steel 1.4301
Mesh size: 0,65 mm
Weight: 16 kg